- Home
- Services
- Fabrication, Electrical & Insulation
- Thermal and industrial insulation
Thermal insulation
Thermal and industrial insulation
Hot insulation saves energy. Cold insulation prevents the system destroying itself — and the vapour barrier is the part that decides which happens.
Insulation looks like a finishing trade and behaves like a process one. On hot systems it controls energy loss and surface temperature; on cold systems it controls condensation, and a defect there causes corrosion under insulation that is invisible until the cladding comes off.
Cold insulation and the vapour barrier
On a chilled or refrigerated system the insulation is not the critical component — the vapour barrier is. Warm humid air carries moisture toward the cold surface, and any interruption in the barrier lets it condense inside the insulation, where it stays. The result is saturated insulation, no thermal performance and corrosion under insulation on the pipe beneath.
- Continuous vapour barrier across the full system, including supports
- Insulated pipe supports so the barrier is not pierced at every hanger
- Vapour stops at intervals and at terminations to limit any ingress
- Sealed penetrations at valves, flanges and instruments
- Multi-layer construction with staggered joints on thicker applications
Hot insulation
- Pipework, vessel, tank and equipment insulation
- Personnel protection to hot surfaces within reach
- Removable and reusable covers for valves and flanges requiring access
- Expansion provision on hot systems that move
- Heat trace accommodation where fitted
Materials
- Mineral wool and rockwool for hot service
- Closed-cell phenolic, PIR and elastomeric for cold service
- Closed-cell spray polyurethane foam for tanks and irregular geometry
- XPS rigid board where compressive strength is required
- Calcium silicate for high-temperature applications
- Acoustic insulation for noise attenuation
Finishing
- Aluminium and stainless steel metal cladding, formed and banded
- Weatherproofing and mastic sealing at joints and terminations
- Lagging, canvas and coating finishes where cladding is not specified
- Identification and flow marking
Standards we work to
- BS 5422
- BS 5970
- ASTM C547
- ASTM C534
- EN ISO 12241
- ASTM C1136
Common questions
What clients ask before awarding
Why is cold insulation harder than hot?
What causes corrosion under insulation?
Do you supply removable covers?
Send us the drawings. We will tell you what it takes.
BOQ, isometrics, specifications or a full tender package. Acknowledged within one working day, with the machine schedule and programme in the offer.